Leaves on the Line

Frome

FRO Western route
CSV JSON

570 delay minutes

The biggest share (21%) of the delay picked up at Frome in the four weeks to 9 December 2023 came from signal, points and power faults.

90% of these minutes were knock-on from something that happened elsewhere first. 99% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track11119%8% 4 a day, more than 3 of the other 4 years3
Signals, points and power11721%16% 4 a day, the most in 5 years2
Weather and structures--7% 0 a day, the least in 5 years-
Autumn275%7% 1 a day, more than 3 of the other 4 years-
External193%4% 1 a day, the most in 5 years-
Network management9216%17% 3 a day, the most in 5 years4
The operators' causes
Train faults11721%16% 4 a day, the most in 5 years1
Traincrew499%11% 2 a day, more than 2 of the other 4 years8
Stations142%3% 1 a day, more than 3 of the other 4 years-
Operations4<1%5% 0 a day, more than 2 of the other 4 years-
Operator, other214%7% 1 a day, more than 1 of the other 4 years-

Period by period

Delay minutes a day, period by period. Gridlines every 10 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
IRBroken/cracked/twisted/buckled/flawed rail89
IBPoints failure (including no fault found)64
OUDelays not Investigated by Network Rail48
TGDriver39
M8Technical failures above the Solebar37
ICTrack circuit failure (including no fault found)32
MSPlanned underpowered or shortformed service and or vehicle, incl. exam set swaps32
J8OTM DAMAGE20
XKNational Grid Power Failure - local area also affected (inc outage, surges, blips where working standby generator/UPS installed)19
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.17
Since 2018
CodeWhat Network Rail loggedMinutes
TGDriver985
IBPoints failure (including no fault found)814
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.657
ICTrack circuit failure (including no fault found)623
MDTechnical failures below the solebar582
M8Technical failures above the Solebar504
ZUNo Cause Identified After investigation by both Parties352
OCSignaller including mis-routing (not ERTM /ETCS related)328
IASignal failure (including no fault found)324
M7Door and Door system faults311