Leaves on the Line

Glossop

GLO North West route
CSV JSON

43 delay minutes

The biggest share (29%) of the delay picked up at Glossop in the four weeks to 9 December 2023 came from autumn leaves.

60% of these minutes were knock-on from something that happened elsewhere first. 84% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024, so they may still move.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideTrains cancelled
Network Rail's causes
Track512%8%-
Signals, points and power--16%-
Weather and structures--7%-
Autumn1329%7%-
External--4%-
Network management921%17%2
The operators' causes
Train faults25%16%-
Traincrew25%11%-
Stations--3%-
Operations--5%-
Operator, other1329%7%-

Quiet enough here (under 100 delay minutes a period on average) that comparing years would mostly be noise, so there's no comparison.

Period by period

Delay minutes a day, period by period. Gridlines every 2 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
Q3NZ Pumps T13
TTLeaf fall Neutral13
OSLate start or delays to Railhead Conditioning or Ghost Train due to its own activity and not in reaction to another incident9
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.5
MSPlanned underpowered or shortformed service and or vehicle, incl. exam set swaps2
TGDriver2
Since 2018
CodeWhat Network Rail loggedMinutes
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.352
MDTechnical failures below the solebar154
IVCutting or embankment earthslip, rock fall or subsidence (not the result of severe weather on the day of failure)138
M1Confirmed Pantograph ADD, associated system faults, positive PANCHEX activations and train borne power switch over systems (AC)123
JLSafety related incident caused by maintenance or infrastructure staff oversight or error (not Operations staff)117
TGDriver115
X2Severe flooding beyond that which could be mitigated on Network Rail infrastructure105
ICTrack circuit failure (including no fault found)102
IHPower Supply And Distribution System Failure80
TOTime lost en-route believed to be Operator cause and information required form operatore (Ops Responsibility)75