Leaves on the Line

Hampton Court

HMC Wessex route
CSV JSON

1,576 delay minutes

The biggest share (21%) of the delay picked up at Hampton Court in the four weeks to 9 December 2023 came from how the network was run.

93% of these minutes were knock-on from something that happened elsewhere first. 99% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track1338%8% 5 a day, more than 3 of the other 4 years4
Signals, points and power17411%16% 6 a day, more than 2 of the other 4 years2
Weather and structures312%7% 1 a day, the most in 5 years-
Autumn31320%7% 11 a day, the most in 5 years-
External13<1%4% 0 a day, more than 3 of the other 4 years-
Network management33621%17% 12 a day, more than 3 of the other 4 years2
The operators' causes
Train faults1067%16% 4 a day, the least in 5 years6
Traincrew1016%11% 4 a day, more than 3 of the other 4 years10
Stations443%3% 2 a day, more than 1 of the other 4 years-
Operations171%5% 1 a day, the most in 5 years8
Operator, other30820%7% 11 a day, more than 3 of the other 4 years2

Period by period

Delay minutes a day, period by period. Gridlines every 20 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
Q3NZ Pumps T291
TTLeaf fall Neutral290
ZSNo Cause ascertainable for a Sub-Threshold Delay causing Threshold Reactionary (where agreed by both parties)106
IRBroken/cracked/twisted/buckled/flawed rail94
I5Possession over-run from planned work91
ICTrack circuit failure (including no fault found)71
TGDriver64
OCSignaller including mis-routing (not ERTM /ETCS related)59
MDTechnical failures below the solebar47
IBPoints failure (including no fault found)45
Since 2018
CodeWhat Network Rail loggedMinutes
ZSNo Cause ascertainable for a Sub-Threshold Delay causing Threshold Reactionary (where agreed by both parties)4,594
ICTrack circuit failure (including no fault found)1,967
TTLeaf fall Neutral1,887
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.1,884
TGDriver1,781
MDTechnical failures below the solebar1,702
IBPoints failure (including no fault found)1,669
M7Door and Door system faults1,336
OCSignaller including mis-routing (not ERTM /ETCS related)1,299
IFTrain Describer/Panel/ARS/SSI/TDM Remote Control failure1,282