Leaves on the Line

High Wycombe

HWY Central route
CSV JSON

848 delay minutes

The biggest share (40%) of the delay picked up at High Wycombe in the four weeks to 9 December 2023 came from faulty trains.

63% of these minutes were knock-on from something that happened elsewhere first. 100% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track111%8% 0 a day, more than 1 of the other 4 years-
Signals, points and power819%16% 3 a day, the least in 5 years-
Weather and structures--7% 0 a day, the least in 5 years-
Autumn627%7% 2 a day, more than 3 of the other 4 years-
External273%4% 1 a day, the least in 5 years-
Network management9311%17% 3 a day, the least in 5 years-
The operators' causes
Train faults33840%16% 12 a day, more than 2 of the other 4 years3
Traincrew10713%11% 4 a day, more than 1 of the other 4 years-
Stations304%3% 1 a day, the least in 5 years-
Operations223%5% 1 a day, more than 1 of the other 4 years1
Operator, other789%7% 3 a day, more than 3 of the other 4 years-

Period by period

Delay minutes a day, period by period. Gridlines every 20 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
M7Door and Door system faults138
MDTechnical failures below the solebar75
TGDriver75
QJSpecial working for leaf-fall track circuit operation41
IBPoints failure (including no fault found)38
I8Animal Strike or Incursion within the control of Network Rail36
M8Technical failures above the Solebar29
VHPassenger Communication cord, door egress or emergency train alarm operated27
XPBRIDGE HIT27
TH(Senior) Conductor/Train Manager26
Since 2018
CodeWhat Network Rail loggedMinutes
MDTechnical failures below the solebar6,167
TGDriver4,527
ICTrack circuit failure (including no fault found)4,395
ZSNo Cause ascertainable for a Sub-Threshold Delay causing Threshold Reactionary (where agreed by both parties)4,311
M8Technical failures above the Solebar2,532
M7Door and Door system faults2,054
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.1,884
IBPoints failure (including no fault found)1,791
MCDiesel Loco failure, defect, attention1,713
IFTrain Describer/Panel/ARS/SSI/TDM Remote Control failure1,622