Leaves on the Line

Kirkby

KIR North West route
CSV JSON

142 delay minutes

Most of the delay picked up at Kirkby in the four weeks to 9 December 2023 came from faulty trains.

4% of these minutes were knock-on from something that happened elsewhere first. 100% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track--8% 0 a day, the least in 5 years-
Signals, points and power32%16% 0 a day, the least in 5 years-
Weather and structures--7% 0 a day, the least in 5 years1
Autumn--7% 0 a day, the least in 5 years-
External--4% 0 a day, the least in 5 years-
Network management64%17% 0 a day, the least in 5 years2
The operators' causes
Train faults12286%16% 4 a day, more than 2 of the other 4 years14
Traincrew54%11% 0 a day, the least in 5 years-
Stations--3% 0 a day, the least in 5 years-
Operations64%5% 0 a day, the least in 5 years-
Operator, other--7% 0 a day, the least in 5 years-

Period by period

Delay minutes a day, period by period. Gridlines every 10 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
M8Technical failures above the Solebar61
MDTechnical failures below the solebar47
MTConfirmed train borne safety system faults (not cab based)10
TOTime lost en-route believed to be Operator cause and information required form operatore (Ops Responsibility)6
ZUNo Cause Identified After investigation by both Parties6
TH(Senior) Conductor/Train Manager5
M7Door and Door system faults4
J0Telecom equipment radio failure (GSM-R)3
Since 2018
CodeWhat Network Rail loggedMinutes
MDTechnical failures below the solebar2,369
TGDriver1,818
M7Door and Door system faults960
TH(Senior) Conductor/Train Manager922
M8Technical failures above the Solebar921
TOTime lost en-route believed to be Operator cause and information required form operatore (Ops Responsibility)695
ICTrack circuit failure (including no fault found)664
IFTrain Describer/Panel/ARS/SSI/TDM Remote Control failure628
Q3NZ Pumps T591
MSPlanned underpowered or shortformed service and or vehicle, incl. exam set swaps438