Leaves on the Line

Liskeard

LSK Western route
CSV JSON

440 delay minutes

The biggest share (20%) of the delay picked up at Liskeard in the four weeks to 9 December 2023 came from signal, points and power faults.

43% of these minutes were knock-on from something that happened elsewhere first. 98% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track5513%8% 2 a day, more than 3 of the other 4 years2
Signals, points and power8620%16% 3 a day, more than 1 of the other 4 years-
Weather and structures215%7% 1 a day, more than 2 of the other 4 years30
Autumn8118%7% 3 a day, more than 3 of the other 4 years-
External82%4% 0 a day, more than 1 of the other 4 years-
Network management4510%17% 2 a day, more than 1 of the other 4 years5
The operators' causes
Train faults5913%16% 2 a day, the least in 5 years1
Traincrew368%11% 1 a day, more than 2 of the other 4 years7
Stations3<1%3% 0 a day, more than 1 of the other 4 years-
Operations2<1%5% 0 a day, more than 1 of the other 4 years-
Operator, other4510%7% 2 a day, more than 1 of the other 4 years-

Period by period

Delay minutes a day, period by period. Gridlines every 20 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
IASignal failure (including no fault found)86
IRBroken/cracked/twisted/buckled/flawed rail43
Q3NZ Pumps T38
TGDriver36
TTLeaf fall Neutral36
QHAdhesion problems due to leaf contamination32
M8Technical failures above the Solebar25
OUDelays not Investigated by Network Rail25
X2Severe flooding beyond that which could be mitigated on Network Rail infrastructure17
M0Confirmed train cab based safety system fault (including GSMR)14
Since 2018
CodeWhat Network Rail loggedMinutes
TGDriver2,344
IASignal failure (including no fault found)2,155
MDTechnical failures below the solebar1,738
IBPoints failure (including no fault found)1,617
ZUNo Cause Identified After investigation by both Parties1,499
IFTrain Describer/Panel/ARS/SSI/TDM Remote Control failure1,344
ZYUnivestigated station overtime System Roll-up Only1,260
X3Lightning Strike - damage to protected systems1,159
XWSevere weather not snow affecting infrastructure the responsibility of Network Rail1,071
J3Axle Counter Failure986