Leaves on the Line

Severn Beach

SVB Western route
CSV JSON

528 delay minutes

The biggest share (27%) of the delay picked up at Severn Beach in the four weeks to 9 December 2023 came from signal, points and power faults.

91% of these minutes were knock-on from something that happened elsewhere first. 95% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track295%8% 1 a day, more than 3 of the other 4 years-
Signals, points and power14127%16% 5 a day, the most in 5 years-
Weather and structures122%7% 0 a day, more than 2 of the other 4 years5
Autumn458%7% 2 a day, more than 2 of the other 4 years-
External11321%4% 4 a day, the most in 5 years1
Network management346%17% 1 a day, more than 1 of the other 4 years1
The operators' causes
Train faults408%16% 1 a day, more than 1 of the other 4 years4
Traincrew10320%11% 4 a day, the most in 5 years14
Stations--3% 0 a day, the least in 5 years-
Operations--5% 0 a day, the least in 5 years-
Operator, other122%7% 0 a day, more than 1 of the other 4 years-

Period by period

Delay minutes a day, period by period. Gridlines every 10 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
XOExternal trees, building or structures encroaching or falling onto network infrastructure (not weather or vandalism)113
TGDriver103
I2AC/DC trip (including no fault or cause found)73
IBPoints failure (including no fault found)38
I4OHLE/third rail power supply failure or reduction30
QICautioning due to railhead leaf contamination30
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.26
M8Technical failures above the Solebar19
OUDelays not Investigated by Network Rail15
OCSignaller including mis-routing (not ERTM /ETCS related)13
Since 2018
CodeWhat Network Rail loggedMinutes
ZUNo Cause Identified After investigation by both Parties1,063
MDTechnical failures below the solebar1,021
TGDriver668
M7Door and Door system faults622
RBPassengers joining/alighting619
M8Technical failures above the Solebar459
MSPlanned underpowered or shortformed service and or vehicle, incl. exam set swaps418
MUDepot operating problem365
Q1Takeback Pumps353
IBPoints failure (including no fault found)348