Tame Bridge Parkway
6 delay minutes
Most of the delay picked up at Tame Bridge Parkway in the four weeks to 9 December 2023 came from signal, points and power faults.
0% of these minutes were knock-on from something that happened elsewhere first. 100% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.
By cause
| Cause | Minutes | Share | Network-wide | Trains cancelled |
|---|---|---|---|---|
| Network Rail's causes | ||||
| Track | - | - | 8% | - |
| Signals, points and power | 6 | 100% | 16% | 1 |
| Weather and structures | - | - | 7% | - |
| Autumn | - | - | 7% | - |
| External | - | - | 4% | - |
| Network management | - | - | 17% | - |
| The operators' causes | ||||
| Train faults | - | - | 16% | - |
| Traincrew | - | - | 11% | - |
| Stations | - | - | 3% | - |
| Operations | - | - | 5% | - |
| Operator, other | - | - | 7% | - |
Quiet enough here (under 100 delay minutes a period on average) that comparing years would mostly be noise, so there's no comparison.
Period by period
The codes behind it
| Code | What Network Rail logged | Minutes |
|---|---|---|
| IB | Points failure (including no fault found) | 6 |
| Code | What Network Rail logged | Minutes |
|---|---|---|
| OC | Signaller including mis-routing (not ERTM /ETCS related) | 164 |
| MD | Technical failures below the solebar | 118 |
| IB | Points failure (including no fault found) | 91 |
| TG | Driver | 69 |
| M7 | Door and Door system faults | 57 |
| JP | Failure to maintain vegetation within network boundaries in accordance with prevailing Network Rail standards | 54 |
| IS | Track defects (other than rail defects) inc. fish plates, wet beds etc. | 37 |
| AK | Safety Ins and mishaps(derailments, fire, chemical spill) in off n/w freight yard or terminal (inc private sdgs affecting FOC | 32 |
| X2 | Severe flooding beyond that which could be mitigated on Network Rail infrastructure | 29 |
| XK | National Grid Power Failure - local area also affected (inc outage, surges, blips where working standby generator/UPS installed) | 29 |