Leaves on the Line

Warminster

WMN Western route
CSV JSON

1,191 delay minutes

The biggest share (37%) of the delay picked up at Warminster in the four weeks to 9 December 2023 came from outside causes like vandalism, cable theft, animals and fires.

54% of these minutes were knock-on from something that happened elsewhere first. 99% of them were agreed between Network Rail and the operators when the file came out on 5 Jan 2024.

By cause

Delay minutes by cause in 2023-24 P09
CauseMinutesShareNetwork-wideA day, against the same period other yearsTrains cancelled
Network Rail's causes
Track514%8% 2 a day, more than 3 of the other 4 years-
Signals, points and power15213%16% 5 a day, more than 3 of the other 4 years3
Weather and structures464%7% 2 a day, the most in 5 years-
Autumn413%7% 1 a day, more than 2 of the other 4 years-
External44337%4% 16 a day, the most in 5 years4
Network management21018%17% 7 a day, the most in 5 years44
The operators' causes
Train faults12510%16% 4 a day, more than 3 of the other 4 years2
Traincrew696%11% 2 a day, the most in 5 years3
Stations11<1%3% 0 a day, more than 1 of the other 4 years-
Operations6<1%5% 0 a day, more than 1 of the other 4 years-
Operator, other383%7% 1 a day, more than 1 of the other 4 years-

Period by period

Delay minutes a day, period by period. Gridlines every 10 minutes. Hatched periods were under 94% agreed when their file came out, so they may still move. Pick a bar to see that period.

The codes behind it

In 2023-24 P09
CodeWhat Network Rail loggedMinutes
XKNational Grid Power Failure - local area also affected (inc outage, surges, blips where working standby generator/UPS installed)413
OCSignaller including mis-routing (not ERTM /ETCS related)85
IBPoints failure (including no fault found)64
OUDelays not Investigated by Network Rail54
IDLevel crossing faults and failure incl. barrow/foot crossings and crossing treadles40
TGDriver38
MDTechnical failures below the solebar38
X2Severe flooding beyond that which could be mitigated on Network Rail infrastructure37
MSPlanned underpowered or shortformed service and or vehicle, incl. exam set swaps28
IFTrain Describer/Panel/ARS/SSI/TDM Remote Control failure23
Since 2018
CodeWhat Network Rail loggedMinutes
MDTechnical failures below the solebar1,493
TGDriver1,355
IBPoints failure (including no fault found)1,204
ICTrack circuit failure (including no fault found)1,058
ISTrack defects (other than rail defects) inc. fish plates, wet beds etc.992
OCSignaller including mis-routing (not ERTM /ETCS related)976
ZUNo Cause Identified After investigation by both Parties880
XKNational Grid Power Failure - local area also affected (inc outage, surges, blips where working standby generator/UPS installed)867
M7Door and Door system faults694
M8Technical failures above the Solebar687